Plumbing and drainage

Quick answer: Bathroom and kitchen in a single-storey house: cold main 20 × 2 and hot main 16 × 2 (multilayer PEX), WC drain and stack DN 100, fixture branches at 2 % slope (20 mm/m).

Water supply and drain pipe sizes, drain slope, roof rainwater and water heater size

How the calculation works

Add rooms (bathroom, kitchen, laundry, WC, outdoor) and their fixtures, the number of floors, the pipe run length and the distance to the connection. The calculator adds up loading units (LU) and discharge units (DU) per section, picks the water pipe size for the chosen material from the tables of the standards, sizes fixture branches, horizontal drains, the stack, the drain under the building and the sewer connection, and checks the slopes. Separate cards calculate roof rainwater and the water heater size, and the slope converter turns %, mm/m and height difference into each other.

Inputs and units

  • Rooms and fixtures: number of each fixture per room and floor
  • Number of floors, pipe run length per floor and distance to the connection (m)
  • Supply pipe material: multilayer PEX, PPR, copper or galvanised steel
  • Expert mode: factor K, slope per section (%), storey height and stock pipe lengths
  • Rainwater: roof plan area (m²), rain intensity and runoff coefficient
  • Water heater: number of people, use per person, temperatures and element power

Formula and assumptions

Water supply (EN 806-3): sum of loading units per section (washbasin 1, shower and sink 2, bath 4, outside tap 5 LU; 1 LU = 0.1 l/s), pipe size from the material table with the limit for the largest single fixture. Drainage (EN 12056-2, system I): Q = K · √ΣDU with K = 0.5 for dwellings, and at least the largest DU of one fixture applies; a stack with a WC is at least DN 100, drains are filled 0.5 inside and 0.7 outside the building. Rainwater: Q = r · A · C. Water heater: Q = m · c · ΔT. Slope: 1 % = 10 mm/m.

Worked example

Single-storey house with a bathroom (washbasin, shower, WC) and kitchen (sink, dishwasher), multilayer PEX pipe: cold water 8 LU – main 20 × 2, hot 5 LU – 16 × 2, house connection 13 LU – 26 × 3. Drainage: ΣDU 4.7, Q = 0.5 · √4.7 = 1.08 l/s, design flow 2 l/s (WC); stack, drain under the building and sewer connection DN 100.

More worked examples

  • Slope 2 % over 5 m of pipe: 20 mm/m, height difference 100 mm (ratio 1 : 50).
  • Roof plan area 100 m², rain 300 l/(s·ha), C = 1: Q = 3 l/s and a DN 70 downpipe. Water heater for 4 people with 50 l a day at 40 °C: 120 l, 6.98 kWh, 2 kW element for 3.7 h.

Loading and discharge units per fixture

FixtureLU (cold / hot)DU (l/s)Branch
Washbasin1 / 10.5DN 40
Shower2 / 20.6DN 50
Bath4 / 40.8DN 50
WC with 6 l cistern1 / –2DN 100
Kitchen sink2 / 20.8DN 50
Washing machine2 / –0.8DN 50
Outside tap5 / –––

What affects real consumption

  • The actual number and type of fixtures and how many are used at the same time.
  • Route length and number of bends – the tables assume usual branch lengths.
  • Mains pressure and the water company's connection rules.
  • Local rain intensity and roof type.

Common mistakes

  • Too little slope or a back-fall on a branch – water stands and traps are siphoned.
  • A stack without a vent above the roof.
  • A WC drain smaller than DN 100 or a pipe getting smaller in the direction of flow.
  • Water heater kept too cool – legionella risk.

Limits of the calculation

  • An estimate, not a design; regulations differ between countries.
  • Pressure losses and fire-fighting water are not included.
  • Gutters are not calculated.

Frequently asked questions

What slope does a drain pipe need?

Fixture branches at least 1 % (10 mm/m), usually 2 %; drains under the building at least 0.5 %, the outside sewer connection at least 1:DN (1 % for DN 100). Slopes above about 5 % are not recommended.

What size drain pipe for a toilet?

DN 100 (110 mm outside diameter), and a stack with a WC at least DN 100. Washbasins and bidets take DN 40; showers, baths, sinks and washing machines DN 50.

How do I convert a slope in percent to millimetres?

Slope in % times 10 gives millimetres per metre: 2 % = 20 mm/m, so over 5 m of pipe the height difference is 100 mm.

What size water pipe does a house need?

By loading units (EN 806-3): a bathroom and kitchen have 8 LU of cold and 5 LU of hot water; with multilayer PEX the cold main is 20 × 2, the hot main 16 × 2 and the house connection 26 × 3.

What pipe size for roof rainwater?

A roof with 100 m² plan area at 300 l/(s·ha) gives 3 l/s; one DN 70 downpipe is enough, and the underground drain is DN 100.

What size water heater for 4 people?

With 50 l of 40 °C hot water per person per day and a tank at 60 °C you need 120 l; a 2 kW element heats it in about 3.7 h.