Guides to plumbing, drainage, heating and air conditioning
Building services are planned before screed and plaster, because they are hard to change afterwards. This category brings together guides and tools for water, heating and cooling. For plumbing and drainage it explains how pipe diameters follow the fixtures they serve, what fall a drain needs inside and outside the house and how rainwater from the roof is calculated. The rainwater tank calculator shows how much water you collect from the roof and which tank size covers your use month by month.
For underfloor heating the page describes how the floor area is split into loops, why a loop must not be too long and how to read the plan with flow and return pipes. The guide on air conditioner size per m² and m³ shows why rules of thumb only give a rough range and how windows, sun and the number of people change the required capacity. You will also find the steps in each calculator, short tips next to the result and common mistakes, such as drains without fall or an air conditioner chosen by floor area alone. Choose a calculator to get pipe sizes, lengths, loops or capacity in kW and BTU/h.
Open the calculator: Plumbing and drainage
Other calculators in this category: Rainwater tank · Underfloor heating · Air conditioner size
Guides
- Air conditioner size per m² and m³: how to calculate kW and BTU/h – Short answer: the air conditioner capacity you need is the room’s highest hourly cooling load in kW. A rule of thumb per m² or m³ only gives a range: the quick estimate in the AC calculator multiplies the floor area by 100 W/m² (20 m² room → 2 kW), while the hour-by-hour calculation for the same room gives 1.38 to 2.01 kW depending on the window, sun, people and insulation. 1 kW = 3412 BTU/h.
Quick tips for your calculation
- An underfloor heating loop must not be too long; split a larger room into several loops of similar length for even flow.
- Air conditioner size per m² is only a rough estimate: large south- and west-facing windows increase the cooling needed considerably. Learn more
- Drain pipes are laid with a fall: too little fall leaves deposits, and a stack without venting can empty the traps.
- Fit a leaf filter and an overflow at the rainwater tank inlet; the first rain from the roof carries the most dirt.
Common mistakes
- Drain without enough fall – Lay pipes with the fall for their diameter and check it with a level.
- One measurement per wall – Measure at two heights and check the diagonals.
- Corners without sealing tape – Reinforce corners, joints and penetrations with tape and collars.
- Spoil removal without bulking – Plan haulage by the loose (bulked) volume.
- Underfloor heating loop too long – Split the room into several loops of similar length.
- Screed without edge strip – Fit edge strip along walls and columns and movement joints to suit the bay size.
- Flooring laid on wet screed – Measure screed moisture and lay only when it is below the permitted limit.
- Air conditioner chosen by m² only – Calculate the cooling load including windows, orientation and occupants.
- Forgotten openings and reveals – Subtract openings and add reveals separately.
How to use the calculator
- 1. Enter the pipe, coils, temperatures and manifold position
2. For each room enter the heated zones as rectangles (L-shape = two zones)
3. Mark areas without pipes as separate zones
4. Choose the layout, pipe spacing, load and floor output
5. Review circuits, lengths, coils, flow and the plan - Each circuit has its own colour and label K1, K2… with its total length. The solid red line is the flow lead and the dashed blue line the return lead to the manifold. Hatched areas have no pipes.
- 1. Enter the location, latitude, month and outdoor and indoor conditions
2. For the room enter the dimensions and the orientation of wall A
3. For each wall, the ceiling and the floor choose the boundary and U-value
4. Add windows with g-value and shading
5. Enter people, lighting, equipment, ventilation and infiltration
6. Compare the peak with the unit's rated capacity - The sensible load changes the air temperature, the latent load removes moisture. The contribution chart shows which items matter most at the peak hour, and the hourly chart when the peak occurs. With several rooms the coincident peak of the building is decisive.
All guide categories · Frequently asked questions about the calculators